ARTHUR MILLER THEATRE
|
 |
|
Specifications at a Glance
Addresses:
Mailing Address:
University Productions
911 N. University
Ann Arbor, MI 48109-1265
Venue Address:
1226 Murfin Ave
Ann Arbor, MI 48109-1212
Seating Capacity:
End stage configuration:
Main Floor
6 Wheelchair
230 Available
Mezzanine
2 Wheelchair
42 Available
Total End Stage Seating: 280
3/4 Thurst Configuration
Main Floor
6 Wheelchair
165 Available
Mezzanine
2 Wheelchair
42 Available
Total Thrust Seating: 215
Stage Specifications:
End stage proscenium (as created by house drapery): 38’ wide x 21’ high
Stage lip to back wall: 22’ 2”
Maximum Stage Thrust (thrust size can be varied): 24’W x 24’D
Maximum out trim of system pipes: 33’ 5”
Rigging:
Single purchase counterweight
21 line sets
Batten length: 42’
Arbor capacity: 7’ high, 1,287 lbs. ea.
House Drapery Hang:
House Curtain – traveler, two panels 25’w x 22’6”
Four pair legs, black, 10’w x 22’h
Two travelers, black, 14’6”w x 25’h
One border, black, 40’w x 15’h
Two borders, black, 40’w x 10’h
Four dead-hung sidetabs on traveler tracks, two ea. SL & SR, black, 9’6”w x 22’6”h
Projection sheet/cyc (white) 40’w x 24’ h
Muslin bounce: 40’ w x 24’ h
Lighting:
Company switches: Off SR, 400 amps, 3 phase, 5 wire; HR tech gallery, 200 amps, 3 phase, 5 wire
House control board: ETC EOS
256 2.4kw dimmers, 6 6kw dimmers, one dimmer per circuit
Full-stage lighting instrumentation
Sound:
House board: Soundcraft Mixer Series II
Aux. isolated power: USR 60 amps, 3 phase, 5 wire cam-lock
Clear-Com production intercom to all production positions
Audio monitor to all dressing rooms
Video monitors located in control room with tie lines to all production positions
Dressing Rooms:
Two dressing rooms, each for sixteen persons located one flight below stage level with adjoining bathrooms with showers
Wig & makeup room located one flight below stage level
Laundry room located one flight below stage level
Loading:
Exterior Loading Door: 5’10”W x 7’H
Note: Special arrangements must be made if users need access to scene shop loading door (dimensions). Permission granted on a case by case basis.
Information Systems:
Wireless - U-M Wireless on-stage and in the auditorium, lobby and dressing rooms.
please refer to http://www.itcom.itd.umich.edu/wireless/ for information regarding access and settings
Wired - ethernet 1000 Base-T, located in box office, control booth and 20 circuits located throughout lobby, backstage, dressing rooms, etc. These circuits can be activated and made available with advance notice.
Note: All wired network circuits are protected by the School of Music, Theatre and Dance's firewall. This firewall is part of the University of Michigan's Virtual Firewall. Please verifying in advance that your needed services are available by contacting the SoMTD's firewall manager at 734-936-5565 or hpr@umich.edu