POWER CENTER  

Specifications at a Glance

Click on the photo to download a QuickTime VR movie for a 360-degree panoramic view of the interior of the Power Center.

Addresses:

Mailing Address:
University Productions
911 N. University
Ann Arbor, MI 48109-1265

Venue Address:
121 N. Fletcher Street
Ann Arbor, MI 48109-2017

Seating Capacity:
· 1368 maximum, including,
· Orchestra 914 + 12WC
· Balcony 455

Stage Specifications:
· Proscenium 55'3-3/4" x 28'
· Depth of stage 42'
· Depth of apron 2'
· Orchestra pit 31' x 8'
· Stage floor to grid 80'

Rigging:
· 62 line sets plus three DS electric lines
· Batten length 31'-5" min.
· Arbor capacity 39 full weights @ 975 lbs

House Drapery Hang:
· Front Curtain - manual, flies out, does not open center, follows apron, gold check
· All drapery is black velour.
· One (1) Teaser, 90'w x 25'h
· One (1) Cyclorama, 47'w x 60'h, (unbleached muslin)
· Four (4) Borders, 60'w x 15'h
· Four (4) Legs, 12'w x 40'h
· Four (4) Legs, 17'w x 40'h
· One (1) Traveler track
· Two (2) Travelers, 40'w x 25'h
· Four (4) Travelers, 32'w x 30'h

Lighting:
· Company switch USR wall, 110/208 3 phase 5 wire, 2 breakers @ 400 amps each
· House board ETC Obsession II
· 476 dimmers
· Full-stage lighting instrumentation

Sound:
· House board Soundcraft K1
· Clear-Com production intercom to all production positions
· Audio monitor to all dressing rooms
· Video monitors located SR, lobby

Dressing Rooms:
· All dressing rooms have mirrors, dressing tables, showers, costume racks and toilets
· Two dressing rooms for four persons located one flight above stage level
· Two dressing rooms for four persons located at stage level
· One ensemble room for 15 persons and one ensemble room for 24 persons located one flight below stage level

Loading:
· Loading doors 18' x 12' located USL

Information Systems:
· Ethernet 100 Base-T — Jacks are located throughout building (stage and lobby) and may be used by arrangement in advance.


· Wireless — Apple Airport Extreme Base Stations (IEEE 802.11b/g Direct Sequence Spread Spectrum 50 Mbps). These base stations provide coverage for the entire main-floor of the auditorium and stage, the entire backstage corridor on the main-floor, and selected parts of the basement and is for use by staff. Renters may gain access to the wireless network by arrangement in advance
Click here for information on how to configure to the University Productions network

-all wired network circuits are protected by the School of Music, Theatre and Dance's firewall. This firewall is part of the University of Michigan's Virtual Firewall. Please verifying in advance that your needed services are available by contacting the SoMTD's firewall manager at 734-936-5565 or hpr@umich.edu

 